Apogee AD-8000 Specifications Page 31

  • Download
  • Add to my manuals
  • Print
  • Page
    / 35
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 30
AD-8000 Operating Manual
Page 31
NTSC Generator: Master Clock
AD-8000
slave to NTSC Generator
DA-88 #1
slave to AD-8000 WC (set to reference EXT
WC) / SMPTE master
DA-88 #2
slave to DA-88 1 'sync in' (set to CHASE)
DA-88 #3
slave to DA-88 2 'sync in' (set to CHASE)
VTR
clock slave to NTSC generator
Transport slave to BRC (via synchronizer)
SMPTE on video tape
DIGITAL CONSOLE
clock slave to AD-8000 AES
TC slave to MTC from DA-88 #1
(for automation)
Tascam RC-848
Remote Control
AES
AES
AMBus
TDIF
AMBus
TDIF
AMBus
TDIF
SYNC
SYNC
Remote 'in' connector
NTSC
video signal
or
black burst
SMPTE-to-MTC Converter
SYNCHRONIZER
Sony 9 pin
RS-422
MTC to Mac serial port
Word Clock
MTC from SY-88 card
SMPTE
Mult
TC D/A
SMPTE
SMPTE
SMPTE
AMBus
Pro Tools
AES or
S/PDIF
NTSC Generator (clock master)/VTR (transport slave)/
DAW/Digital Console/DA-88s
Although this setup is fairly complex, it is designed to illustrate the flow of time code, NTSC video signal (or black burst), and word clock.
Understanding the overall concept allows you to add or remove different pieces of equipment while keeping the system synchronized.
DAW
clock slave to AD-8000
MTC slave to SMPTE-to-MTC Converter
NTSC
video signal
or
black burst
Page view 30